Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Southern Medical University ; (12): 414-420, 2018.
Article in Chinese | WPRIM | ID: wpr-690453

ABSTRACT

<p><b>OBJECTIVE</b>To develop a near-infrared fluorescence imaging system based on the fluorescence properties of methylene blue.</p><p><b>METHODS</b>According to the optical properties of methylene blue, we used a custom-made specific LED light source and an interference filter, a CCD camera and other relevant components to construct the near-infrared fluorescence imaging system. We tested the signal-to-background ratio (SBR) of this imaging system for detecting methylene blue under different experimental conditions and analyzed the SBR in urine samples collected from 15 Wistar rats with intravenous injection of methylene blue at the doses of 0, 1.4, 1.6, 1.8, or 2.0 0 mg/kg methylene blue.</p><p><b>RESULTS</b>The SBR of this imaging system for detecting methylene blue was affected by the concentration of methylene blue and the distance from the sample (P<0.05). In the urine samples from Wistar rats, the SBR varied with the the injection dose, and the rats injected with 1.6 mg/kg methylene blue showed the highest SBR (8.71∓0.20) in the urine (P<0.05).</p><p><b>CONCLUSION</b>This near-infrared fluorescence imaging system is useful for fluorescence detection of methylene blue and can be used for real-time recognition of ureters during abdominal surgery.</p>

2.
Journal of Southern Medical University ; (12): 434-442, 2018.
Article in Chinese | WPRIM | ID: wpr-690450

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the differences in dielectric properties (relative permittivity and conductivity) between the mucosal surface and serosal surface of malignant colorectal tissues, adjacent tissues at 1 cm and 3 cm from the tumor focus and normal colorectal tissues.</p><p><b>METHODS</b>The dielectric properties of the mucosal and serosal surface of malignant colorectal tissues, adjacent tissues (1 cm and 3 cm) and normal colorectal tissues from 39 patients with colorectal cancer were measured with an open-ended coaxial probe within the frequency range of 50 MHz-3 GHz, and the corresponding dielectric properties were analyzed respectively; statistical tests of the data were used to analyze the dielectric properties at 6 specific frequency points.</p><p><b>RESULTS</b>The dielectric properties were significantly higher in the malignant mucosa surface than in the adjacent tissues and normal colorectal tissues at the 6 specific frequency points (P<0.01). The dielectric properties decreased progressively in adjacent tissues at 1 cm and 3 cm and normal mucosa surface. The mucosal and serosal surface of malignant tissues showed significant differences in dielectric properties at 64 MHz, 128 MHz, 298 MHz, 433 MHz, and 915 MHz (P<0.01) but not at 2450 MHz (P>0.01), but such differences were not observed in normal tissues (P>0.01).</p><p><b>CONCLUSION</b>The dielectric properties of the mucosal surface of the mucosal decrease in the order of malignant colorectal tissue, adjacent tissues at 1 cm and 3 cm from the tumor foci and normal colorectal tissues. The dielectric properties are higher in the mucosal surface than in the serosal surface in the malignant tissue, but comparable in normal colorectal tissues.</p>

SELECTION OF CITATIONS
SEARCH DETAIL